CBR-7 Installation and Testing 501-281, Rev C.0
1
Installation
and Testing
5 Mbit/s
Repeater
Carrier-band
to Single-mode
Fiber Optic
Models
CBR-7AC
CBR-7DC
This manual describes the procedures for installing and testing the CBR-7 Fiber-Optic Repeaters.
o For an explanation of how to install the coaxial cable part of the carrierband network, see
Relcom’s Carrier-band Network Handbook.
o For an explanation of how fiber optics works, see Relcom’s Guide to Industrial Fiber Optics.
o For an explanation about how repeaters work, and CBR-7 system design information, see
Relcom’s CBR-7 System Design Application Note, document 501-276.
o For technical specifications, see the CBR-7 product specification, document PS-029.
Vedere la pagina 0
1 2 3 4 5 6 ... 10 11

Sommario

Pagina 1 - CBR-7DC

CBR-7 Installation and Testing 501-281, Rev C.0 1 Installation and Testing 5 Mbit/s Repeater Carrier-band to Single-mode Fiber Optic Models

Pagina 2

CBR-7 Installation and Testing 501-281, Rev C.0 10 Receiver side With all the optical components connected, disconnect the CBR-7 at the receiver

Pagina 3

CBR-7 Installation and Testing 501-281, Rev C.0 11 Here is an example: The top of the screen is at -10 dB. There are two

Pagina 4

CBR-7 Installation and Testing 501-281, Rev C.0 2 Repeater Installation The Repeater is connected to segments of the Carrier-band network like an

Pagina 5

CBR-7 Installation and Testing 501-281, Rev C.0 3 Hazardous Area Warning For both AC and DC Repeaters, users are warned not to disconnect power

Pagina 6 - Fiber-Optic Testing

CBR-7 Installation and Testing 501-281, Rev C.0 4 Testing A self-testing capability is provided for checking the operation of the Repeater before

Pagina 7 - -11.2dBm

CBR-7 Installation and Testing 501-281, Rev C.0 5 Troubleshooting During normal Repeater operation, the PWR light is ON, the two ACTIVE lights ar

Pagina 8

CBR-7 Installation and Testing 501-281, Rev C.0 6 Fiber-Optic Testing When the CBR-7 repeaters and the optical components are installed, they m

Pagina 9

CBR-7 Installation and Testing 501-281, Rev C.0 7 Attenuation Measurement Determine the light output level of the CBR-7 transmitter. Disconne

Pagina 10 - Loss must be at least 48 dB

CBR-7 Installation and Testing 501-281, Rev C.0 8 From the example above, if the light measured at the receiver is -11.2dBm then the Measured Att

Pagina 11

CBR-7 Installation and Testing 501-281, Rev C.0 9 Return Loss CBR-7 performance depends on low return losses (reflections) of the optical compo